VOMROIndustrial Technology

Measurable leak tightness without a water bath

Air leak (leak tightness) tester

An air leak tester fills the part with air at a defined pressure, isolates it from the source and measures how much the pressure drops over a defined time. If the drop is below the limit value, the part is accepted as leak-tight. Compared with immersion in a water tank, it gives a measurable, repeatable result that can be recorded. VOMRO leak testers are configured together with a sealing fixture specific to your part.

Metal product housing clamped to a perforated test plate with toggle clamps, a connection line, a sensor in front and a laptop showing the measurement curve behind
The part is clamped in the fixture and pressurized; the result is given by measuring the pressure drop.
MethodPressure decay; optional differential pressure
ApplicationHousing, valve, tank, enclosure, radiator
Data loggingMeasured value, result, serial number

Why it matters

A leak cannot be seen, but it can be caught if measured correctly.

Porosity in a cast housing, an under-tightened seal or a micro crack in a weld: the part passes visual inspection but leaks oil, water or gas in use. For manufacturers of automotive parts, home appliances, valves and electronic enclosures, leak testing is often a mandatory end-of-line step.

Looking for bubbles in a water bath seems simple, but the result depends on the operator, the part gets wet and no measurable value can be recorded. The pressure decay method performs the same test on every part under the same conditions and records the result as a number.

01

How does the pressure decay method work?

The test consists of four steps. Fill: the part is filled with air up to the test pressure. Stabilize: the air heated during filling and the flexing part are allowed to settle. Measure: the part is isolated from the air supply and the pressure drop is measured over the defined time. Exhaust: the pressure is released and the part is unclamped.

The stabilization step has the greatest influence on the reliability of the result. If it is too short, a good part may appear to leak; if it is longer than necessary, the cycle time increases. The right times are determined by trials with your part.

  • Adjustable fill, stabilization, measurement and exhaust times
  • Testing with positive pressure or vacuum
  • Test pressure and limit values saved as recipes
02

How is the pressure drop converted into a leak rate?

The pressure drop alone is sufficient for comparing parts with each other, but customer specifications usually require a leak rate (for example cm³/min or mbar·l/s). The leak rate is calculated approximately as test volume × pressure drop ÷ measurement time.

Example: a drop of 2 mbar in 10 seconds in a volume of 0.5 litres corresponds to a leak of 0.5 × 2 ÷ 10 = 0.1 mbar·l/s, which is about 6 cm³/min. The same leak creates a smaller pressure drop in a larger volume. That is why small leaks are harder to catch in large-volume parts and why keeping the dead volume inside the fixture small is important.

Industrial pressure transmitter with a stainless steel body and threaded connection
Measurement sensitivity depends on the pressure sensor, selected with a range suited to the test pressure.
03

Why is temperature the biggest source of error?

The pressure of air in a closed volume changes with temperature. A part that comes warm from the previous process shows a pressure drop as it cools during the measurement and appears to leak. Parts that have just come out of washing, welding or an oven are therefore the most common cause of false rejects.

  • Making sure parts reach ambient temperature before the test
  • Adjusting the stabilization time to the part's temperature condition
  • Using the differential pressure method with a reference volume for small leaks
  • Making sure the air supply is dry and its pressure stable

In the differential pressure method, the test part is compared with a leak-free reference volume under the same conditions; since a large part of the ambient effects acts on both sides at the same time, they cancel each other out.

04

The sealing fixture: the invisible half of the test

However sensitive the leak tester is, if the fixture that closes the part's openings leaks, the result is wrong. The fixture closes the open ports of the part with sealed plugs or heads, pressurizes the part from a single, correct point and holds it without deformation under pressure.

  • Part-specific seals and plugs; easy replacement for wear
  • Pneumatic clamping with two-hand control or a protective cover
  • Connection design that keeps dead volume small
  • Part presence sensor and wrong-part prevention
Automation cabinet with terminals, relays and a DIN-rail mounted control board
Valve control, sensor measurement and logging are managed by a single control system in the test station's cabinet.
05

How do you make sure the instrument measures correctly?

The most dangerous situation in leak testing is a leaking part passing. To prevent this, the instrument must be verified at regular intervals with a leak of known value. A calibrated leak (master leak) is connected to the fixture or test line, and it is checked that the instrument measures this leak at the correct value.

In addition to verification, a repeatability study at the start with known-good and known-leaking samples shows that the limit value has been chosen safely. The test software can remind operators of periodic verification at the start of the shift and prevent testing from starting without verification.

06

When is the pressure decay method not enough?

The pressure decay method meets most of the typical leak tightness requirements for automotive and home appliance parts. However, when very small leaks must be detected, for example at the levels required for refrigerant circuits or hermetic electronic enclosures, helium or tracer gas methods are used. These methods are a different class of equipment.

When you share your part's leak limit and volume, we assess openly at the start of the project whether the pressure decay or differential pressure method can measure this limit reliably.

Technical options

Features configured for your part

Test pressure, measuring range and cycle time are set according to the part volume and leak limit.

Air leak tester configuration options
FeatureOptions
MethodPressure decay; differential pressure with a reference volume for small leaks
Test pressurePositive pressure or vacuum, according to the part's operating condition
Test stepsFill, stabilize, measure, exhaust; recipe-based times
ResultPressure drop and calculated leak rate
FixturePart-specific sealed heads and plugs, pneumatic clamping
ChannelsSingle channel, or multiple channels testing several parts at the same time
VerificationCalibrated leak connection, periodic verification reminder
Data loggingSerial number, measured value, result; CSV / MES transfer
SafetyTwo-hand control or protective cover, pressure relief

Project process

From part to reliable test

The instrument and fixture are tuned together through trials with your part.

  1. 01

    We review the part

    We determine the part volume, openings, test pressure and leak limit.

  2. 02

    We design the fixture

    We design the sealing heads, plugs and clamping system.

  3. 03

    We tune it through trials

    We set the times and limit values with good and leaking samples.

  4. 04

    We commission it on your line

    We verify with a calibrated leak and hand over with operator training and a spare seal list.

Frequently asked questions

About air leak testing

A technical drawing or sample of the part and the accepted leak limit are needed to determine the right method.

Why pressure decay instead of a water bath test?

A water bath test depends on the operator's attention, wets the part and does not give a numerical value. A pressure decay test measures every part under the same conditions, records the result and requires no drying.

How long does one test take?

The time depends on the part volume, test pressure and leak limit. A few seconds may be enough for small parts; for large-volume or flexible parts, the stabilization time increases. We determine the target cycle time through trials with your part.

Does it also show where the leak is?

The pressure decay method shows whether the part leaks and how much, but not where. If needed, the location of the leak on a rejected part is found separately with foam or water.

Can plastic and flexible parts be tested?

Yes, but flexible parts may expand under pressure and cause a pressure drop. This effect is reduced by supporting the part with the fixture and extending the stabilization time.

What determines the price?

Channel count, measurement sensitivity, the need for differential pressure, fixture complexity, level of automation and logging requirements.

Let's start from your part

Let's verify leak tightness by measuring, not guessing.

Share the drawing or a photo of the part, the test pressure and the leak limit; we will prepare a suitable instrument and fixture design and a quotation.

We develop products for companies, manufacturers and institutions. We do not take on student, thesis or hobby projects, or requests for PCB fabrication/assembly only, board repair or board copying.