RO water treatment controller board

The RO water treatment controller board is the brain of a reverse osmosis unit. It manages the inlet valve and the high-pressure pump, protects the pump when the water supply is cut, flushes the membrane at set intervals and monitors quality by measuring the conductivity of the product water. The VOMRO board is configured for residential, commercial and industrial RO units according to your needs for inputs and outputs, display and branding.

Drawing of an RO controller board with a display showing the conductivity value, pre-filters, membrane housings and a high-pressure pump
The controller board manages the pump, valves and membrane line together.
ApplicationResidential, commercial and industrial RO units
MeasurementConductivity / TDS, pressure, level
ProtectionDry run, leak, quality alarm

Why it matters

Membrane life depends on the decisions of the controller board.

The most expensive parts of an RO unit are the membrane and the pump. A pump running without water is damaged quickly; a membrane that is not flushed clogs and loses efficiency. Simple timer boards cannot detect these conditions, and the fault is only noticed when water quality deteriorates.

A well-designed controller board protects the pump, flushes the membrane regularly and measures quality continuously. For the unit manufacturer, this means fewer service calls and a more reliable product.

01

The RO unit's operating cycle

In a residential RO unit, the basic cycle is as follows: when the tank is full, the high-pressure switch opens and the board stops the pump and closes the inlet valve. When the tap is opened and tank pressure drops, the board opens the inlet valve and, if mains water is available, starts the pump. If there is no mains pressure, the low-pressure switch reports this and the pump is not started.

In industrial units, a float or level sensor in the product water tank is usually used instead of a pressure switch. The board starts and stops production according to the level in the tank; if the level in the raw water tank is low, it puts the pump into protection.

  • Inlet solenoid valve and high-pressure pump control
  • Low- and high-pressure switch inputs
  • Float / level inputs for product and raw water tanks
Control unit developed for a water treatment unit, with its connections
The control unit combines all inputs and outputs of the unit on a single board.
02

Conductivity and TDS measurement

As dissolved salts in water increase, the water's ability to conduct electricity increases. The board measures this value with a conductivity cell and displays it in µS/cm. The TDS (total dissolved solids) value is calculated from conductivity using a conversion factor; this factor is usually chosen between 0.5 and 0.7 depending on the water composition. That is why the TDS reading is an estimate; the quantity actually measured is conductivity.

Conductivity changes significantly with temperature; the same water shows a lower value when cold. For a correct comparison, the measurement is temperature-compensated to a 25 °C reference. When feed and product water are measured together, the membrane's salt rejection rate can be calculated; a drop in this rate is an early sign that the membrane is wearing out.

  • Temperature-compensated conductivity measurement
  • Adjustable TDS conversion factor
  • Salt rejection rate from feed and product water measurement
03

Automatic membrane flushing

Salt and dirt build up on the membrane surface over time. During flushing, the valve on the concentrate line opens and the membrane surface is swept with high flow. The board can be set to flush automatically every time the unit starts, after certain running times or during long idle periods.

Flushing time and frequency should be set according to feed water quality and the membrane manufacturer's recommendations. Flushing too often wastes water; flushing too rarely leads to premature membrane clogging.

  • Start-up, periodic and post-standby flushing
  • Adjustable flushing duration and interval
  • Filter and membrane replacement reminder
04

Protections and alarms

Dry-run protection stops the pump when there is no mains or raw water and retries at set intervals. Continuous-run protection treats it as a leak or fault if the pump runs for too long without the tank filling. An optional leak sensor closes the inlet valve when it detects water under the unit.

If the product water conductivity exceeds the set limit, a quality alarm is raised; in industrial units, a drain valve then opens to prevent poor-quality water from going to the product tank. Alarm states can be reported on the display, by an indicator light or externally via a relay output.

  • Dry-run and continuous-run protection
  • Leak sensor input
  • Quality alarm and drain valve output
Checking a water treatment and dosing controller board on a test rig
Protection functions are checked scenario by scenario on the board test rig.
05

Power supply, display and OEM branding

In residential units, pumps and valves mostly run on 24 VDC and the board is powered by an adapter. In commercial and industrial units, 230 VAC pump motors need to be driven via a contactor or relay. The board's power supply and output structure are chosen according to the pumps and valves in your unit.

Display options range from a simple LED indicator to a segment or graphic display showing conductivity and status information. For manufacturers producing in series, the front panel, logo, start-up screen and menu language can be prepared for your brand. With an optional Modbus or GSM module, units can be monitored remotely.

  • 12/24 VDC or 230 VAC output structure
  • LED, segment or graphic display
  • OEM logo, front panel and menu language; Modbus / GSM monitoring
06

Can it replace your existing board?

If you want to replace a board that has supply problems or whose features are no longer sufficient, we can prepare a compatible board by examining the existing board's connections, mounting dimensions and operating logic. In this case the new board can be fitted without changing your wiring or housing.

In replacement projects, the most important step is correctly understanding all operating scenarios of the existing board. That is why we start with a sample board and a description of how the unit works, and test the first boards in your unit.

Technical options

Features configured for your unit

The number of inputs and outputs, power supply and display type are finalised according to your unit's design.

RO water treatment controller board configuration options
FeatureOptions
OutputsInlet valve, pump, flush valve, drain valve, alarm relay
InputsLow / high-pressure switch, float or level sensor, leak sensor
MeasurementTemperature-compensated conductivity / TDS; optional feed water measurement
FunctionsAutomatic flushing, dry-run and continuous-run protection, filter reminder
Power supply12/24 VDC; contactor / relay drive for 230 VAC pumps
DisplayLED indicator, segment or graphic display
CommunicationOptional remote monitoring via Modbus RTU or GSM
OEMLogo, front panel design, menu language, parameter presets

How we work

From a board that fits your unit to series production

The board moves into series production after being tested in your unit.

  1. 01

    We review the unit

    We review the pump, valve, sensor and power supply setup and, if there is an existing board, its connections.

  2. 02

    We configure it

    We define the input-output, display, protection and flushing functions for your unit.

  3. 03

    We test samples

    We try the first boards in your unit with all operating and fault scenarios.

  4. 04

    We move to series production

    We deliver the approved board in series, tested and labelled.

Frequently asked questions

About the RO controller board

Sharing your unit's capacity, pump and valve types and your expected annual quantity speeds up the assessment.

Can the same board be used for residential and industrial RO?

The basic logic is similar, but the power supply, output power and input types differ. Residential units typically use 24 VDC and pressure switches, while industrial units use 230 VAC pumps and level sensors. The board is configured according to the unit class.

Why can the TDS value differ from a laboratory measurement?

The board measures conductivity and calculates the TDS value using a factor. A laboratory measures the dissolved substances directly. When the factor is adjusted to the water composition, the difference decreases, but the TDS reading should always be treated as an estimate.

What is the minimum order quantity?

If one of the existing configurations meets your needs, you can start with small quantities. For projects with OEM branding and a custom front panel, quantity and delivery schedule are agreed together.

Can I monitor my units remotely?

Yes. With an optional Modbus or GSM module, production, conductivity, alarms and filter status can be monitored remotely. This makes maintenance planning easier for manufacturers with a service network.

Can the board's firmware be updated?

Yes. Firmware updates can be done via a service connection; parameters come preset for your unit model and are protected against unauthorized changes by a service menu.

Tell us about your unit

Let's prepare the right controller board for your RO unit.

Share the unit type, pump and valve setup and your expected quantity; let's define a suitable configuration and quotation together.

We develop products for companies, manufacturers and institutions. We do not take on student, thesis or hobby projects, or requests for PCB fabrication/assembly only, board repair or board copying.