VOMROIndustrial Technology

Control and protection for screw compressors

Compressor controller board

A compressor controller board runs the compressor loaded or unloaded according to line pressure, starts the motor safely with star-delta, monitors discharge temperature and motor protection, and reminds you of maintenance intervals. The VOMRO controller board replaces control units that have failed or whose spares cannot be found, adapted to your compressor's existing sensors and electrical setup; it offers remote monitoring and multi-compressor sequencing via Modbus.

Drawing of a screw compressor body with a control panel showing line pressure, discharge temperature and load status, and an air receiver
Pressure, temperature and operating status monitored on one panel.
ApplicationScrew compressors, brand-independent adaptation
ControlPressure band, star-delta, load/unload
MonitoringMaintenance counters, Modbus, sequencing

Why it matters

When the controller board fails, the compressor stops; when the compressor stops, the factory stops.

Compressed air is the shared energy of many lines, from pneumatic cylinders to paint booths and from packaging machines to CNC machine tools. When a compressor's control unit fails, finding the original part can take weeks, or the model may no longer be produced.

Replacing a mechanically sound compressor just because of its controller board is an unnecessary investment. An adaptable controller board not only gets the compressor running again but is also an opportunity to improve energy consumption and maintenance tracking.

01

What does a compressor controller board do?

In a screw compressor, the controller board continuously measures line pressure with a pressure transmitter. When pressure falls to the lower limit, it opens the inlet valve and loads the compressor; when the upper limit is reached, it switches to unloaded operation. It stops a compressor that has been unloaded for a certain time, avoiding unnecessary energy consumption.

The motor draws a high current at start-up. The board limits this current by operating the star-delta contactors in the correct sequence and timing, and interlocks the contactor transitions so that two contactors cannot pull in at the same time.

  • Load / unload / standby management according to line pressure
  • Star-delta starting and contactor interlocking
  • Discharge temperature, motor and phase protection
Industrial control cabinet with contactors, fuses and cable ducts
The controller board works together with the contactors and protective devices in the compressor cabinet.
02

How do the pressure band and load/unload operation affect energy consumption?

Running a compressor at a higher pressure than needed means spending extra energy every hour. According to a widely accepted rule of thumb in the industry, lowering the operating pressure by 1 bar can reduce the compressor's energy consumption by about 7 percent. The exact effect depends on the compressor type and the condition of the network.

Unloaded running also consumes energy; the motor turns but delivers no air. Setting the pressure band and unload time correctly balances unnecessary unloaded running against frequent starts and stops. Because the board records loaded and total running hours separately, you can evaluate this balance with data.

  • Lower and upper pressure limits set to your needs
  • Limits on unload time and starts per hour
  • Reporting of load ratio and running hours
03

Which protection functions are included?

Most compressor failures grow because warning signs are not seen in time. The controller board stops the compressor safely in critical situations and clearly shows the cause of the fault on the display.

  • High discharge temperature: first a warning, then a stop if the limit is exceeded
  • Motor overload and thermal protection: monitoring of the motor protection contact
  • Phase sequence and phase loss: preventing reverse rotation and two-phase running
  • Emergency stop and door / safety contacts
  • Sensor fault: safe stop when the pressure or temperature sensor is disconnected
  • Separator differential pressure: clogging warning if a suitable sensor is fitted
04

Maintenance counters and service planning

The air filter, oil filter, oil and oil separator must be replaced at specific running hours. Delayed maintenance can lead to expensive failures such as oil carry-over, high temperature and damage to the airend.

The board keeps a separate counter for each maintenance item, warns when it is due and resets the counter when the maintenance is done. For service companies, maintenance history and fault records make it easier to assess the compressor's condition before a visit.

  • Separate counters for air filter, oil filter, oil and separator
  • Total and loaded running hours
  • Time-stamped fault and event logs
05

Remote monitoring and multi-compressor sequencing

In plants with several compressors, each machine running to its own pressure setting causes the compressors to work against each other and creates unnecessary unloaded time. The sequencing function brings compressors online according to demand and rotates the lead compressor to equalize running hours.

Via Modbus communication, pressure, temperature, status and alarms can be transferred to a SCADA system or a remote monitoring dashboard. For variable-speed compressors, the speed reference can be sent to the drive via an analogue output or Modbus.

  • Modbus RTU (RS-485) and optional Modbus TCP
  • Remote start / stop input
  • Lead–lag sequencing and running-hour equalization
06

Adapting it to your existing compressor

The board is configured independently of the brand, based on the compressor's existing sensors and wiring diagram. The output type of the pressure transmitter (usually 4–20 mA), the type of temperature sensor (PT100, PT1000 or NTC) and the voltage of the contactor and valve coils are the key inputs for the adaptation.

The front panel cut-out and mounting method are chosen to fit the existing cabinet. We complete the first installation together with your compressor service company or ourselves, with a commissioning test. For compressors still under warranty, we recommend checking the manufacturer's warranty conditions beforehand.

Controller board undergoing embedded firmware debugging and communication testing
Control logic and communication are tested with compressor scenarios.

Technical options

Features configured for your compressor

Input and output types are finalised at the quotation stage based on the existing sensors and electrical setup.

Compressor controller board configuration options
FeatureOptions
Pressure measurement4–20 mA pressure transmitter input; optional second pressure input
Temperature measurementPT100, PT1000 or NTC; discharge and optional additional points
Digital inputsEmergency stop, motor protection, phase monitor, remote start, door / safety
Relay outputsMain, star and delta contactors; load valve; drain; common alarm
ControlPressure band, unload time, starts-per-hour limit, automatic restart
MaintenanceAir filter, oil filter, oil and separator counters; event log
CommunicationModbus RTU (RS-485); optional Modbus TCP or cellular remote monitoring
Variable-speed driveAnalogue (0–10 V / 4–20 mA) or Modbus speed reference
InterfaceGraphic display, menu in Turkish or English, password-protected service settings

Adaptation process

From your compressor's data to commissioning

The board is prepared according to the actual connections of your existing compressor.

  1. 01

    We gather the information

    We review the wiring diagram, sensor types, panel dimensions and the current fault situation.

  2. 02

    We configure the board

    We prepare the inputs, outputs, pressure band and protection settings.

  3. 03

    We commission

    We test starting, load/unload transitions and protections on the compressor.

  4. 04

    We provide support

    We hand over with a settings record, operating instructions and service support.

Frequently asked questions

About compressor controller boards

Sharing your compressor's nameplate data and a photo of the cabinet speeds up the adaptation.

Which compressor brands does it fit?

The board is not tied to a specific brand. It is adapted by reviewing the compressor's sensor types, contactor arrangement and wiring diagram. For some factory control systems that use a proprietary communication protocol, the scope of adaptation is assessed separately.

Can it be used on variable-speed compressors?

Yes. The board can send a speed reference to the drive according to line pressure; the drive's own protection and fault information can be read via digital inputs or Modbus.

Will I lose the settings of my old controller board?

We record the existing pressure and temperature settings before commissioning. The new board starts with these values and, if needed, they are optimized together to reduce energy consumption.

How many compressors can it manage together?

The sequencing function is designed for managing several compressors on the same network together via Modbus. The number of compressors and the network layout are finalised at the project stage.

How is the price determined?

The number of inputs and outputs, display type, communication options, commissioning needs and quantity determine the price. Bulk purchase and own-brand board options for service companies are assessed separately.

Let's start from your compressor

Let's get your compressor running reliably again.

Share the compressor's nameplate data, wiring diagram or a photo of the cabinet; we will prepare a suitable controller board configuration and a quotation.

We develop products for companies, manufacturers and institutions. We do not take on student, thesis or hobby projects, or requests for PCB fabrication/assembly only, board repair or board copying.